WSL2-Linux-Kernel/arch/powerpc/perf
sukadev@linux.vnet.ibm.com 56f12bee55 powerpc/perf/hv-24x7: Simplify catalog_read()
catalog_read() implements the read interface for the sysfs file

	/sys/bus/event_source/devices/hv_24x7/interface/catalog

It essentially takes a buffer, an offset and count as parameters
to the read() call.  It makes a hypervisor call to read a specific
page from the catalog and copy the required bytes into the given
buffer. Each call to catalog_read() returns at most one 4K page.

Given these requirements, we should be able to simplify the
catalog_read().

Signed-off-by: Sukadev Bhattiprolu <sukadev@linux.vnet.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
2014-10-07 16:57:10 +11:00
..
Makefile powerpc/perf: Add kconfig option for hypervisor provided counters 2014-03-24 09:48:32 +11:00
bhrb.S powerpc/perf: Add basic assembly code to read BHRB entries on POWER8 2013-04-26 16:11:11 +10:00
callchain.c powerpc/perf: Fix ABIv2 kernel backtraces 2014-09-09 19:02:45 +10:00
core-book3s.c powerpc: Make a bunch of things static 2014-09-25 23:14:41 +10:00
core-fsl-emb.c powerpc/perf: add 2 additional performance monitor counters for e6500 core 2013-08-07 18:38:03 -05:00
e500-pmu.c powerpc/perf: Add stalled-cycles events 2013-01-10 17:00:56 +11:00
e6500-pmu.c powerpc/perf: Add e6500 PMU driver 2013-08-07 18:38:04 -05:00
hv-24x7-catalog.h powerpc/perf: Add 24x7 interface headers 2014-03-24 09:48:29 +11:00
hv-24x7.c powerpc/perf/hv-24x7: Simplify catalog_read() 2014-10-07 16:57:10 +11:00
hv-24x7.h powerpc/perf: Add 24x7 interface headers 2014-03-24 09:48:29 +11:00
hv-common.c powerpc/perf: Add a shared interface to get gpci version and capabilities 2014-03-24 09:48:30 +11:00
hv-common.h powerpc/perf: Add macros for defining event fields & formats 2014-03-24 09:48:31 +11:00
hv-gpci.c powerpc, perf: Use common PMU interrupt disabled code 2014-07-05 11:21:51 +02:00
hv-gpci.h powerpc/perf: Add hv_gpci interface header 2014-03-24 09:48:29 +11:00
mpc7450-pmu.c powerpc/perf: Pass the struct perf_events down to compute_mmcr() 2014-07-28 14:30:47 +10:00
power4-pmu.c powerpc/perf: Pass the struct perf_events down to compute_mmcr() 2014-07-28 14:30:47 +10:00
power5+-pmu.c powerpc/perf: Pass the struct perf_events down to compute_mmcr() 2014-07-28 14:30:47 +10:00
power5-pmu.c powerpc/perf: Pass the struct perf_events down to compute_mmcr() 2014-07-28 14:30:47 +10:00
power6-pmu.c powerpc/perf: Pass the struct perf_events down to compute_mmcr() 2014-07-28 14:30:47 +10:00
power7-events-list.h powerpc/perf: Make some new raw event codes available in sysfs 2014-03-24 09:48:23 +11:00
power7-pmu.c powerpc/perf: Pass the struct perf_events down to compute_mmcr() 2014-07-28 14:30:47 +10:00
power8-pmu.c powerpc/perf: Add per-event excludes on Power8 2014-07-28 14:30:58 +10:00
ppc970-pmu.c powerpc/perf: Pass the struct perf_events down to compute_mmcr() 2014-07-28 14:30:47 +10:00