зеркало из https://github.com/microsoft/lisa.git
verify_timesync_ptp - support multiple ptp devices.
In some Linux VMs you may see multiple PTP devices listed. One example is for Accelerated Networking the Mellanox mlx5 driver also creates a /dev/ptp device. Because the initialization order can be different each time Linux boots,the PTP device corresponding to the Azure host might be /dev/ptp0 or it might be /dev/ptp1. To determine which PTP device corresponds to the Azure host, you can check the clock_name file. Atleast one of the PTP devices should have a clock_name of 'hyperv'.
This commit is contained in:
Родитель
17e0b6fcbc
Коммит
7cdf089430
|
@ -20,7 +20,7 @@ from lisa import (
|
|||
create_timer,
|
||||
)
|
||||
from lisa.operating_system import CpuArchitecture, Redhat, Suse
|
||||
from lisa.tools import Cat, Chrony, Dmesg, Hwclock, Lscpu, Ntp, Ntpstat, Service
|
||||
from lisa.tools import Cat, Chrony, Dmesg, Hwclock, Ls, Lscpu, Ntp, Ntpstat, Service
|
||||
from lisa.tools.date import Date
|
||||
from lisa.tools.lscpu import CpuType
|
||||
from lisa.util import constants
|
||||
|
@ -94,14 +94,28 @@ class TimeSync(TestSuite):
|
|||
assert_that(dmesg.get_output()).contains(self.ptp_registered_msg)
|
||||
|
||||
# 2. PTP device name is hyperv.
|
||||
# In some Linux VMs you may see multiple PTP devices listed.
|
||||
# One example is for Accelerated Networking the Mellanox mlx5 driver also
|
||||
# creates a /dev/ptp device. Because the initialization order can be different
|
||||
# each time Linux boots, the PTP device corresponding to the Azure host might
|
||||
# be /dev/ptp0 or it might be /dev/ptp1.
|
||||
# To determine which PTP device corresponds to the Azure host, you can check the
|
||||
# clock_name file. At least one of the PTP devices should have
|
||||
# a clock_name of 'hyperv'.
|
||||
cat = node.tools[Cat]
|
||||
clock_name_result = cat.run("/sys/class/ptp/ptp0/clock_name")
|
||||
assert_that(clock_name_result.stdout).described_as(
|
||||
f"ptp clock name should be 'hyperv', meaning the Azure host, "
|
||||
f"but it is {clock_name_result.stdout}, more info please refer "
|
||||
f"https://docs.microsoft.com/en-us/azure/virtual-machines/linux/time-sync#check-for-ptp-clock-source" # noqa: E501
|
||||
).is_equal_to("hyperv")
|
||||
|
||||
ls = node.tools[Ls]
|
||||
ptp_devices = ls.list_dir("/sys/class/ptp")
|
||||
ptp_hyperv_device = None
|
||||
for ptp_device in ptp_devices:
|
||||
clock_name_result = cat.run(
|
||||
f"{ptp_device}clock_name", sudo=True, shell=True, force_run=True
|
||||
)
|
||||
if clock_name_result.stdout == "hyperv":
|
||||
ptp_hyperv_device = ptp_device
|
||||
assert_that(ptp_hyperv_device).described_as(
|
||||
"There should be at least one PTP device with name 'hyperv', more info"
|
||||
" please refer https://docs.microsoft.com/en-us/azure/virtual-machines/linux/time-sync#check-for-ptp-clock-source" # noqa: E501
|
||||
).is_not_none()
|
||||
# 3. When accelerated network is enabled, multiple PTP devices will
|
||||
# be available, the names of ptp are changeable, create the symlink
|
||||
# /dev/ptp_hyperv to whichever /dev/ptp entry corresponds to the Azure host.
|
||||
|
|
Загрузка…