зеркало из https://github.com/mozilla/pjs.git
480 строки
20 KiB
Python
480 строки
20 KiB
Python
# ***** BEGIN LICENSE BLOCK *****
|
|
# Version: MPL 1.1/GPL 2.0/LGPL 2.1
|
|
#
|
|
# The contents of this file are subject to the Mozilla Public License Version
|
|
# 1.1 (the "License"); you may not use this file except in compliance with
|
|
# the License. You may obtain a copy of the License at
|
|
# http://www.mozilla.org/MPL/
|
|
#
|
|
# Software distributed under the License is distributed on an "AS IS" basis,
|
|
# WITHOUT WARRANTY OF ANY KIND, either express or implied. See the License
|
|
# for the specific language governing rights and limitations under the
|
|
# License.
|
|
#
|
|
# The Original Code is mozilla.org code.
|
|
#
|
|
# The Initial Developer of the Original Code is Joel Maher.
|
|
#
|
|
# Portions created by the Initial Developer are Copyright (C) 2010
|
|
# the Initial Developer. All Rights Reserved.
|
|
#
|
|
# Contributor(s):
|
|
# Joel Maher <joel.maher@gmail.com> (Original Developer)
|
|
# Clint Talbert <cmtalbert@gmail.com>
|
|
#
|
|
# Alternatively, the contents of this file may be used under the terms of
|
|
# either the GNU General Public License Version 2 or later (the "GPL"), or
|
|
# the GNU Lesser General Public License Version 2.1 or later (the "LGPL"),
|
|
# in which case the provisions of the GPL or the LGPL are applicable instead
|
|
# of those above. If you wish to allow use of your version of this file only
|
|
# under the terms of either the GPL or the LGPL, and not to allow others to
|
|
# use your version of this file under the terms of the MPL, indicate your
|
|
# decision by deleting the provisions above and replace them with the notice
|
|
# and other provisions required by the GPL or the LGPL. If you do not delete
|
|
# the provisions above, a recipient may use your version of this file under
|
|
# the terms of any one of the MPL, the GPL or the LGPL.
|
|
#
|
|
# ***** END LICENSE BLOCK *****
|
|
|
|
import sys
|
|
import os
|
|
import time
|
|
import tempfile
|
|
|
|
# We need to know our current directory so that we can serve our test files from it.
|
|
SCRIPT_DIRECTORY = os.path.abspath(os.path.realpath(os.path.dirname(sys.argv[0])))
|
|
|
|
from runreftest import RefTest
|
|
from runreftest import ReftestOptions
|
|
from automation import Automation
|
|
import devicemanager, devicemanagerADB, devicemanagerSUT
|
|
from remoteautomation import RemoteAutomation
|
|
|
|
class RemoteOptions(ReftestOptions):
|
|
def __init__(self, automation):
|
|
ReftestOptions.__init__(self, automation)
|
|
|
|
defaults = {}
|
|
defaults["logFile"] = "reftest.log"
|
|
# app, xrePath and utilityPath variables are set in main function
|
|
defaults["remoteTestRoot"] = None
|
|
defaults["app"] = ""
|
|
defaults["xrePath"] = ""
|
|
defaults["utilityPath"] = ""
|
|
|
|
self.add_option("--remote-app-path", action="store",
|
|
type = "string", dest = "remoteAppPath",
|
|
help = "Path to remote executable relative to device root using only forward slashes. Either this or app must be specified, but not both.")
|
|
defaults["remoteAppPath"] = None
|
|
|
|
self.add_option("--deviceIP", action="store",
|
|
type = "string", dest = "deviceIP",
|
|
help = "ip address of remote device to test")
|
|
defaults["deviceIP"] = None
|
|
|
|
self.add_option("--devicePort", action="store",
|
|
type = "string", dest = "devicePort",
|
|
help = "port of remote device to test")
|
|
defaults["devicePort"] = 20701
|
|
|
|
self.add_option("--remote-product-name", action="store",
|
|
type = "string", dest = "remoteProductName",
|
|
help = "Name of product to test - either fennec or firefox, defaults to fennec")
|
|
defaults["remoteProductName"] = "fennec"
|
|
|
|
self.add_option("--remote-webserver", action="store",
|
|
type = "string", dest = "remoteWebServer",
|
|
help = "IP Address of the webserver hosting the reftest content")
|
|
defaults["remoteWebServer"] = automation.getLanIp()
|
|
|
|
self.add_option("--http-port", action = "store",
|
|
type = "string", dest = "httpPort",
|
|
help = "port of the web server for http traffic")
|
|
defaults["httpPort"] = automation.DEFAULT_HTTP_PORT
|
|
|
|
self.add_option("--ssl-port", action = "store",
|
|
type = "string", dest = "sslPort",
|
|
help = "Port for https traffic to the web server")
|
|
defaults["sslPort"] = automation.DEFAULT_SSL_PORT
|
|
|
|
self.add_option("--remote-logfile", action="store",
|
|
type = "string", dest = "remoteLogFile",
|
|
help = "Name of log file on the device relative to device root. PLEASE USE ONLY A FILENAME.")
|
|
defaults["remoteLogFile"] = None
|
|
|
|
self.add_option("--enable-privilege", action="store_true", dest = "enablePrivilege",
|
|
help = "add webserver and port to the user.js file for remote script access and universalXPConnect")
|
|
defaults["enablePrivilege"] = False
|
|
|
|
self.add_option("--pidfile", action = "store",
|
|
type = "string", dest = "pidFile",
|
|
help = "name of the pidfile to generate")
|
|
defaults["pidFile"] = ""
|
|
|
|
self.add_option("--bootstrap", action="store_true", dest = "bootstrap",
|
|
help = "test with a bootstrap addon required for native Fennec")
|
|
defaults["bootstrap"] = False
|
|
|
|
self.add_option("--dm_trans", action="store",
|
|
type = "string", dest = "dm_trans",
|
|
help = "the transport to use to communicate with device: [adb|sut]; default=sut")
|
|
defaults["dm_trans"] = "sut"
|
|
|
|
defaults["localLogName"] = None
|
|
|
|
self.set_defaults(**defaults)
|
|
|
|
def verifyRemoteOptions(self, options):
|
|
# Ensure our defaults are set properly for everything we can infer
|
|
options.remoteTestRoot = self._automation._devicemanager.getDeviceRoot() + '/reftest'
|
|
options.remoteProfile = options.remoteTestRoot + "/profile"
|
|
|
|
# Verify that our remotewebserver is set properly
|
|
if (options.remoteWebServer == None or
|
|
options.remoteWebServer == '127.0.0.1'):
|
|
print "ERROR: Either you specified the loopback for the remote webserver or ",
|
|
print "your local IP cannot be detected. Please provide the local ip in --remote-webserver"
|
|
return None
|
|
|
|
# One of remoteAppPath (relative path to application) or the app (executable) must be
|
|
# set, but not both. If both are set, we destroy the user's selection for app
|
|
# so instead of silently destroying a user specificied setting, we error.
|
|
if (options.remoteAppPath and options.app):
|
|
print "ERROR: You cannot specify both the remoteAppPath and the app"
|
|
return None
|
|
elif (options.remoteAppPath):
|
|
options.app = options.remoteTestRoot + "/" + options.remoteAppPath
|
|
elif (options.app == None):
|
|
# Neither remoteAppPath nor app are set -- error
|
|
print "ERROR: You must specify either appPath or app"
|
|
return None
|
|
|
|
if (options.xrePath == None):
|
|
print "ERROR: You must specify the path to the controller xre directory"
|
|
return None
|
|
else:
|
|
# Ensure xrepath is a full path
|
|
options.xrePath = os.path.abspath(options.xrePath)
|
|
|
|
# Default to <deviceroot>/reftest/reftest.log
|
|
if (options.remoteLogFile == None):
|
|
options.remoteLogFile = 'reftest.log'
|
|
|
|
options.localLogName = options.remoteLogFile
|
|
options.remoteLogFile = options.remoteTestRoot + '/' + options.remoteLogFile
|
|
|
|
# Ensure that the options.logfile (which the base class uses) is set to
|
|
# the remote setting when running remote. Also, if the user set the
|
|
# log file name there, use that instead of reusing the remotelogfile as above.
|
|
if (options.logFile):
|
|
# If the user specified a local logfile name use that
|
|
options.localLogName = options.logFile
|
|
|
|
options.logFile = options.remoteLogFile
|
|
|
|
if (options.pidFile != ""):
|
|
f = open(options.pidFile, 'w')
|
|
f.write("%s" % os.getpid())
|
|
f.close()
|
|
|
|
# TODO: Copied from main, but I think these are no longer used in a post xulrunner world
|
|
#options.xrePath = options.remoteTestRoot + self._automation._product + '/xulrunner'
|
|
#options.utilityPath = options.testRoot + self._automation._product + '/bin'
|
|
return options
|
|
|
|
class ReftestServer:
|
|
""" Web server used to serve Reftests, for closer fidelity to the real web.
|
|
It is virtually identical to the server used in mochitest and will only
|
|
be used for running reftests remotely.
|
|
Bug 581257 has been filed to refactor this wrapper around httpd.js into
|
|
it's own class and use it in both remote and non-remote testing. """
|
|
|
|
def __init__(self, automation, options, scriptDir):
|
|
self._automation = automation
|
|
self._utilityPath = options.utilityPath
|
|
self._xrePath = options.xrePath
|
|
self._profileDir = options.serverProfilePath
|
|
self.webServer = options.remoteWebServer
|
|
self.httpPort = options.httpPort
|
|
self.scriptDir = scriptDir
|
|
self.pidFile = options.pidFile
|
|
self.shutdownURL = "http://%(server)s:%(port)s/server/shutdown" % { "server" : self.webServer, "port" : self.httpPort }
|
|
|
|
def start(self):
|
|
"Run the Refest server, returning the process ID of the server."
|
|
|
|
env = self._automation.environment(xrePath = self._xrePath)
|
|
env["XPCOM_DEBUG_BREAK"] = "warn"
|
|
if self._automation.IS_WIN32:
|
|
env["PATH"] = env["PATH"] + ";" + self._xrePath
|
|
|
|
args = ["-g", self._xrePath,
|
|
"-v", "170",
|
|
"-f", os.path.join(self.scriptDir, "reftest/components/httpd.js"),
|
|
"-e", "const _PROFILE_PATH = '%(profile)s';const _SERVER_PORT = '%(port)s'; const _SERVER_ADDR ='%(server)s';" %
|
|
{"profile" : self._profileDir.replace('\\', '\\\\'), "port" : self.httpPort, "server" : self.webServer },
|
|
"-f", os.path.join(self.scriptDir, "server.js")]
|
|
|
|
xpcshell = os.path.join(self._utilityPath,
|
|
"xpcshell" + self._automation.BIN_SUFFIX)
|
|
self._process = self._automation.Process([xpcshell] + args, env = env)
|
|
pid = self._process.pid
|
|
if pid < 0:
|
|
print "Error starting server."
|
|
sys.exit(2)
|
|
self._automation.log.info("INFO | remotereftests.py | Server pid: %d", pid)
|
|
|
|
if (self.pidFile != ""):
|
|
f = open(self.pidFile + ".xpcshell.pid", 'w')
|
|
f.write("%s" % pid)
|
|
f.close()
|
|
|
|
def ensureReady(self, timeout):
|
|
assert timeout >= 0
|
|
|
|
aliveFile = os.path.join(self._profileDir, "server_alive.txt")
|
|
i = 0
|
|
while i < timeout:
|
|
if os.path.exists(aliveFile):
|
|
break
|
|
time.sleep(1)
|
|
i += 1
|
|
else:
|
|
print "Timed out while waiting for server startup."
|
|
self.stop()
|
|
sys.exit(1)
|
|
|
|
def stop(self):
|
|
try:
|
|
c = urllib2.urlopen(self.shutdownURL)
|
|
c.read()
|
|
c.close()
|
|
|
|
rtncode = self._process.poll()
|
|
if (rtncode == None):
|
|
self._process.terminate()
|
|
except:
|
|
self._process.kill()
|
|
|
|
class RemoteReftest(RefTest):
|
|
remoteApp = ''
|
|
|
|
def __init__(self, automation, devicemanager, options, scriptDir):
|
|
RefTest.__init__(self, automation)
|
|
self._devicemanager = devicemanager
|
|
self.scriptDir = scriptDir
|
|
self.remoteApp = options.app
|
|
self.remoteProfile = options.remoteProfile
|
|
self.remoteTestRoot = options.remoteTestRoot
|
|
self.remoteLogFile = options.remoteLogFile
|
|
self.localLogName = options.localLogName
|
|
self.pidFile = options.pidFile
|
|
if self.automation.IS_DEBUG_BUILD:
|
|
self.SERVER_STARTUP_TIMEOUT = 180
|
|
else:
|
|
self.SERVER_STARTUP_TIMEOUT = 90
|
|
|
|
def findPath(self, paths, filename = None):
|
|
for path in paths:
|
|
p = path
|
|
if filename:
|
|
p = os.path.join(p, filename)
|
|
if os.path.exists(self.getFullPath(p)):
|
|
return path
|
|
return None
|
|
|
|
def startWebServer(self, options):
|
|
""" Create the webserver on the host and start it up """
|
|
remoteXrePath = options.xrePath
|
|
remoteUtilityPath = options.utilityPath
|
|
localAutomation = Automation()
|
|
localAutomation.IS_WIN32 = False
|
|
localAutomation.IS_LINUX = False
|
|
localAutomation.IS_MAC = False
|
|
localAutomation.UNIXISH = False
|
|
hostos = sys.platform
|
|
if (hostos == 'mac' or hostos == 'darwin'):
|
|
localAutomation.IS_MAC = True
|
|
elif (hostos == 'linux' or hostos == 'linux2'):
|
|
localAutomation.IS_LINUX = True
|
|
localAutomation.UNIXISH = True
|
|
elif (hostos == 'win32' or hostos == 'win64'):
|
|
localAutomation.BIN_SUFFIX = ".exe"
|
|
localAutomation.IS_WIN32 = True
|
|
|
|
paths = [options.xrePath, localAutomation.DIST_BIN, self.automation._product, os.path.join('..', self.automation._product)]
|
|
options.xrePath = self.findPath(paths)
|
|
if options.xrePath == None:
|
|
print "ERROR: unable to find xulrunner path for %s, please specify with --xre-path" % (os.name)
|
|
sys.exit(1)
|
|
paths.append("bin")
|
|
paths.append(os.path.join("..", "bin"))
|
|
|
|
xpcshell = "xpcshell"
|
|
if (os.name == "nt"):
|
|
xpcshell += ".exe"
|
|
|
|
if (options.utilityPath):
|
|
paths.insert(0, options.utilityPath)
|
|
options.utilityPath = self.findPath(paths, xpcshell)
|
|
if options.utilityPath == None:
|
|
print "ERROR: unable to find utility path for %s, please specify with --utility-path" % (os.name)
|
|
sys.exit(1)
|
|
|
|
options.serverProfilePath = tempfile.mkdtemp()
|
|
self.server = ReftestServer(localAutomation, options, self.scriptDir)
|
|
self.server.start()
|
|
|
|
self.server.ensureReady(self.SERVER_STARTUP_TIMEOUT)
|
|
options.xrePath = remoteXrePath
|
|
options.utilityPath = remoteUtilityPath
|
|
|
|
def stopWebServer(self, options):
|
|
self.server.stop()
|
|
|
|
def createReftestProfile(self, options, profileDir, reftestlist):
|
|
RefTest.createReftestProfile(self, options, profileDir, reftestlist, server=options.remoteWebServer)
|
|
|
|
# Turn off the locale picker screen
|
|
fhandle = open(os.path.join(profileDir, "user.js"), 'a')
|
|
fhandle.write("""
|
|
user_pref("browser.firstrun.show.localepicker", false);
|
|
user_pref("font.size.inflation.emPerLine", 0);
|
|
user_pref("font.size.inflation.minTwips", 0);
|
|
user_pref("reftest.remote", true);
|
|
user_pref("toolkit.telemetry.prompted", true);
|
|
user_pref("reftest.uri", "%s");
|
|
""" % reftestlist)
|
|
|
|
#workaround for jsreftests.
|
|
if options.enablePrivilege:
|
|
fhandle.write("""
|
|
user_pref("capability.principal.codebase.p2.granted", "UniversalPreferencesWrite UniversalXPConnect UniversalBrowserWrite UniversalPreferencesRead UniversalBrowserRead");
|
|
user_pref("capability.principal.codebase.p2.id", "http://%s:%s");
|
|
""" % (options.remoteWebServer, options.httpPort))
|
|
|
|
# Close the file
|
|
fhandle.close()
|
|
|
|
if (self._devicemanager.pushDir(profileDir, options.remoteProfile) == None):
|
|
raise devicemanager.FileError("Failed to copy profiledir to device")
|
|
|
|
def copyExtraFilesToProfile(self, options, profileDir):
|
|
RefTest.copyExtraFilesToProfile(self, options, profileDir)
|
|
if (self._devicemanager.pushDir(profileDir, options.remoteProfile) == None):
|
|
raise devicemanager.FileError("Failed to copy extra files to device")
|
|
|
|
def registerExtension(self, browserEnv, options, profileDir, extraArgs = ['-silent'] ):
|
|
if options.bootstrap:
|
|
return
|
|
|
|
self.automation.log.info("REFTEST INFO | runreftest.py | Performing extension manager registration: start.\n")
|
|
# Because our startProcess code doesn't return until fennec starts we just give it
|
|
# a maxTime of 20 secs before timing it out and ensuring it is dead.
|
|
# Besides registering the extension, this works around fennec bug 570027
|
|
status = self.automation.runApp(None, browserEnv, options.app, profileDir,
|
|
extraArgs,
|
|
utilityPath = options.utilityPath,
|
|
xrePath=options.xrePath,
|
|
symbolsPath=options.symbolsPath,
|
|
maxTime = 20)
|
|
# We don't care to call |processLeakLog()| for this step.
|
|
self.automation.log.info("\nREFTEST INFO | runreftest.py | Performing extension manager registration: end.")
|
|
|
|
def getManifestPath(self, path):
|
|
return path
|
|
|
|
def cleanup(self, profileDir):
|
|
# Pull results back from device
|
|
if (self.remoteLogFile):
|
|
self._devicemanager.getFile(self.remoteLogFile, self.localLogName)
|
|
self._devicemanager.removeDir(self.remoteProfile)
|
|
self._devicemanager.removeDir(self.remoteTestRoot)
|
|
RefTest.cleanup(self, profileDir)
|
|
if (self.pidFile != ""):
|
|
try:
|
|
os.remove(self.pidFile)
|
|
os.remove(self.pidFile + ".xpcshell.pid")
|
|
except:
|
|
print "Warning: cleaning up pidfile '%s' was unsuccessful from the test harness" % self.pidFile
|
|
|
|
def main():
|
|
dm_none = devicemanagerADB.DeviceManagerADB(None, None)
|
|
automation = RemoteAutomation(dm_none)
|
|
parser = RemoteOptions(automation)
|
|
options, args = parser.parse_args()
|
|
|
|
if (options.deviceIP == None):
|
|
print "Error: you must provide a device IP to connect to via the --device option"
|
|
sys.exit(1)
|
|
|
|
if (options.dm_trans == "adb"):
|
|
if (options.deviceIP):
|
|
dm = devicemanagerADB.DeviceManagerADB(options.deviceIP, options.devicePort)
|
|
else:
|
|
dm = dm_none
|
|
else:
|
|
dm = devicemanagerSUT.DeviceManagerSUT(options.deviceIP, options.devicePort)
|
|
automation.setDeviceManager(dm)
|
|
|
|
if (options.remoteProductName != None):
|
|
automation.setProduct(options.remoteProductName)
|
|
|
|
# Set up the defaults and ensure options are set
|
|
options = parser.verifyRemoteOptions(options)
|
|
if (options == None):
|
|
print "ERROR: Invalid options specified, use --help for a list of valid options"
|
|
sys.exit(1)
|
|
|
|
if not options.ignoreWindowSize:
|
|
parts = dm.getInfo('screen')['screen'][0].split()
|
|
width = int(parts[0].split(':')[1])
|
|
height = int(parts[1].split(':')[1])
|
|
if (width < 1050 or height < 1050):
|
|
print "ERROR: Invalid screen resolution %sx%s, please adjust to 1366x1050 or higher" % (width, height)
|
|
sys.exit(1)
|
|
|
|
automation.setAppName(options.app)
|
|
automation.setRemoteProfile(options.remoteProfile)
|
|
automation.setRemoteLog(options.remoteLogFile)
|
|
reftest = RemoteReftest(automation, dm, options, SCRIPT_DIRECTORY)
|
|
|
|
# Hack in a symbolic link for jsreftest
|
|
os.system("ln -s ../jsreftest " + str(os.path.join(SCRIPT_DIRECTORY, "jsreftest")))
|
|
|
|
# Dynamically build the reftest URL if possible, beware that args[0] should exist 'inside' the webroot
|
|
manifest = args[0]
|
|
if os.path.exists(os.path.join(SCRIPT_DIRECTORY, args[0])):
|
|
manifest = "http://" + str(options.remoteWebServer) + ":" + str(options.httpPort) + "/" + args[0]
|
|
elif os.path.exists(args[0]):
|
|
manifestPath = os.path.abspath(args[0]).split(SCRIPT_DIRECTORY)[1].strip('/')
|
|
manifest = "http://" + str(options.remoteWebServer) + ":" + str(options.httpPort) + "/" + manifestPath
|
|
else:
|
|
print "ERROR: Could not find test manifest '%s'" % manifest
|
|
sys.exit(1)
|
|
|
|
# Start the webserver
|
|
reftest.startWebServer(options)
|
|
|
|
procName = options.app.split('/')[-1]
|
|
if (dm.processExist(procName)):
|
|
dm.killProcess(procName)
|
|
|
|
#an example manifest name to use on the cli
|
|
# manifest = "http://" + options.remoteWebServer + "/reftests/layout/reftests/reftest-sanity/reftest.list"
|
|
try:
|
|
cmdlineArgs = ["-reftest", manifest]
|
|
if options.bootstrap:
|
|
cmdlineArgs = []
|
|
reftest.runTests(manifest, options, cmdlineArgs)
|
|
except:
|
|
print "TEST-UNEXPECTED-FAIL | | exception while running reftests"
|
|
reftest.stopWebServer(options)
|
|
sys.exit(1)
|
|
|
|
reftest.stopWebServer(options)
|
|
|
|
if __name__ == "__main__":
|
|
main()
|
|
|