2005-04-17 02:20:36 +04:00
|
|
|
/*
|
|
|
|
* processor_thermal.c - Passive cooling submodule of the ACPI processor driver
|
|
|
|
*
|
|
|
|
* Copyright (C) 2001, 2002 Andy Grover <andrew.grover@intel.com>
|
|
|
|
* Copyright (C) 2001, 2002 Paul Diefenbaugh <paul.s.diefenbaugh@intel.com>
|
|
|
|
* Copyright (C) 2004 Dominik Brodowski <linux@brodo.de>
|
|
|
|
* Copyright (C) 2004 Anil S Keshavamurthy <anil.s.keshavamurthy@intel.com>
|
|
|
|
* - Added processor hotplug support
|
|
|
|
*
|
|
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
*
|
|
|
|
* This program is free software; you can redistribute it and/or modify
|
|
|
|
* it under the terms of the GNU General Public License as published by
|
|
|
|
* the Free Software Foundation; either version 2 of the License, or (at
|
|
|
|
* your option) any later version.
|
|
|
|
*
|
|
|
|
* This program is distributed in the hope that it will be useful, but
|
|
|
|
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
|
|
|
* General Public License for more details.
|
|
|
|
*
|
|
|
|
* You should have received a copy of the GNU General Public License along
|
|
|
|
* with this program; if not, write to the Free Software Foundation, Inc.,
|
|
|
|
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
|
|
|
*
|
|
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
*/
|
|
|
|
|
|
|
|
#include <linux/kernel.h>
|
|
|
|
#include <linux/module.h>
|
|
|
|
#include <linux/init.h>
|
|
|
|
#include <linux/cpufreq.h>
|
|
|
|
|
|
|
|
#include <asm/uaccess.h>
|
|
|
|
|
|
|
|
#include <acpi/acpi_bus.h>
|
|
|
|
#include <acpi/processor.h>
|
|
|
|
#include <acpi/acpi_drivers.h>
|
|
|
|
|
2009-07-29 00:45:54 +04:00
|
|
|
#define PREFIX "ACPI: "
|
|
|
|
|
2005-04-17 02:20:36 +04:00
|
|
|
#define ACPI_PROCESSOR_CLASS "processor"
|
|
|
|
#define _COMPONENT ACPI_PROCESSOR_COMPONENT
|
2007-02-13 06:42:12 +03:00
|
|
|
ACPI_MODULE_NAME("processor_thermal");
|
2005-04-17 02:20:36 +04:00
|
|
|
|
|
|
|
#ifdef CONFIG_CPU_FREQ
|
|
|
|
|
|
|
|
/* If a passive cooling situation is detected, primarily CPUfreq is used, as it
|
|
|
|
* offers (in most cases) voltage scaling in addition to frequency scaling, and
|
|
|
|
* thus a cubic (instead of linear) reduction of energy. Also, we allow for
|
|
|
|
* _any_ cpufreq driver and not only the acpi-cpufreq driver.
|
|
|
|
*/
|
|
|
|
|
2008-01-17 10:51:23 +03:00
|
|
|
#define CPUFREQ_THERMAL_MIN_STEP 0
|
|
|
|
#define CPUFREQ_THERMAL_MAX_STEP 3
|
|
|
|
|
2008-03-05 19:31:29 +03:00
|
|
|
static DEFINE_PER_CPU(unsigned int, cpufreq_thermal_reduction_pctg);
|
2005-04-17 02:20:36 +04:00
|
|
|
static unsigned int acpi_thermal_cpufreq_is_init = 0;
|
|
|
|
|
2012-02-06 20:17:11 +04:00
|
|
|
#define reduction_pctg(cpu) \
|
|
|
|
per_cpu(cpufreq_thermal_reduction_pctg, phys_package_first_cpu(cpu))
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Emulate "per package data" using per cpu data (which should really be
|
|
|
|
* provided elsewhere)
|
|
|
|
*
|
|
|
|
* Note we can lose a CPU on cpu hotunplug, in this case we forget the state
|
|
|
|
* temporarily. Fortunately that's not a big issue here (I hope)
|
|
|
|
*/
|
|
|
|
static int phys_package_first_cpu(int cpu)
|
|
|
|
{
|
|
|
|
int i;
|
|
|
|
int id = topology_physical_package_id(cpu);
|
|
|
|
|
|
|
|
for_each_online_cpu(i)
|
|
|
|
if (topology_physical_package_id(i) == id)
|
|
|
|
return i;
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
2005-04-17 02:20:36 +04:00
|
|
|
static int cpu_has_cpufreq(unsigned int cpu)
|
|
|
|
{
|
|
|
|
struct cpufreq_policy policy;
|
2004-09-16 19:07:00 +04:00
|
|
|
if (!acpi_thermal_cpufreq_is_init || cpufreq_get_policy(&policy, cpu))
|
2005-12-21 09:29:00 +03:00
|
|
|
return 0;
|
|
|
|
return 1;
|
2005-04-17 02:20:36 +04:00
|
|
|
}
|
|
|
|
|
2005-08-05 08:44:28 +04:00
|
|
|
static int acpi_thermal_cpufreq_notifier(struct notifier_block *nb,
|
|
|
|
unsigned long event, void *data)
|
2005-04-17 02:20:36 +04:00
|
|
|
{
|
|
|
|
struct cpufreq_policy *policy = data;
|
|
|
|
unsigned long max_freq = 0;
|
|
|
|
|
|
|
|
if (event != CPUFREQ_ADJUST)
|
|
|
|
goto out;
|
|
|
|
|
2008-03-05 19:31:29 +03:00
|
|
|
max_freq = (
|
|
|
|
policy->cpuinfo.max_freq *
|
2012-02-06 20:17:11 +04:00
|
|
|
(100 - reduction_pctg(policy->cpu) * 20)
|
2008-03-05 19:31:29 +03:00
|
|
|
) / 100;
|
2005-04-17 02:20:36 +04:00
|
|
|
|
|
|
|
cpufreq_verify_within_limits(policy, 0, max_freq);
|
|
|
|
|
2005-08-05 08:44:28 +04:00
|
|
|
out:
|
2005-04-17 02:20:36 +04:00
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static struct notifier_block acpi_thermal_cpufreq_notifier_block = {
|
|
|
|
.notifier_call = acpi_thermal_cpufreq_notifier,
|
|
|
|
};
|
|
|
|
|
2008-01-17 10:51:23 +03:00
|
|
|
static int cpufreq_get_max_state(unsigned int cpu)
|
|
|
|
{
|
|
|
|
if (!cpu_has_cpufreq(cpu))
|
|
|
|
return 0;
|
|
|
|
|
|
|
|
return CPUFREQ_THERMAL_MAX_STEP;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int cpufreq_get_cur_state(unsigned int cpu)
|
|
|
|
{
|
|
|
|
if (!cpu_has_cpufreq(cpu))
|
|
|
|
return 0;
|
|
|
|
|
2012-02-06 20:17:11 +04:00
|
|
|
return reduction_pctg(cpu);
|
2008-01-17 10:51:23 +03:00
|
|
|
}
|
|
|
|
|
|
|
|
static int cpufreq_set_cur_state(unsigned int cpu, int state)
|
|
|
|
{
|
2012-02-06 20:17:11 +04:00
|
|
|
int i;
|
|
|
|
|
2008-01-17 10:51:23 +03:00
|
|
|
if (!cpu_has_cpufreq(cpu))
|
|
|
|
return 0;
|
|
|
|
|
2012-02-06 20:17:11 +04:00
|
|
|
reduction_pctg(cpu) = state;
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Update all the CPUs in the same package because they all
|
|
|
|
* contribute to the temperature and often share the same
|
|
|
|
* frequency.
|
|
|
|
*/
|
|
|
|
for_each_online_cpu(i) {
|
|
|
|
if (topology_physical_package_id(i) ==
|
|
|
|
topology_physical_package_id(cpu))
|
|
|
|
cpufreq_update_policy(i);
|
|
|
|
}
|
2008-01-17 10:51:23 +03:00
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
2005-08-05 08:44:28 +04:00
|
|
|
void acpi_thermal_cpufreq_init(void)
|
|
|
|
{
|
2005-04-17 02:20:36 +04:00
|
|
|
int i;
|
|
|
|
|
2005-08-05 08:44:28 +04:00
|
|
|
i = cpufreq_register_notifier(&acpi_thermal_cpufreq_notifier_block,
|
|
|
|
CPUFREQ_POLICY_NOTIFIER);
|
2005-04-17 02:20:36 +04:00
|
|
|
if (!i)
|
|
|
|
acpi_thermal_cpufreq_is_init = 1;
|
|
|
|
}
|
|
|
|
|
2005-08-05 08:44:28 +04:00
|
|
|
void acpi_thermal_cpufreq_exit(void)
|
|
|
|
{
|
2005-04-17 02:20:36 +04:00
|
|
|
if (acpi_thermal_cpufreq_is_init)
|
2005-08-05 08:44:28 +04:00
|
|
|
cpufreq_unregister_notifier
|
|
|
|
(&acpi_thermal_cpufreq_notifier_block,
|
|
|
|
CPUFREQ_POLICY_NOTIFIER);
|
2005-04-17 02:20:36 +04:00
|
|
|
|
|
|
|
acpi_thermal_cpufreq_is_init = 0;
|
|
|
|
}
|
|
|
|
|
2005-08-05 08:44:28 +04:00
|
|
|
#else /* ! CONFIG_CPU_FREQ */
|
2008-01-17 10:51:23 +03:00
|
|
|
static int cpufreq_get_max_state(unsigned int cpu)
|
|
|
|
{
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int cpufreq_get_cur_state(unsigned int cpu)
|
|
|
|
{
|
|
|
|
return 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int cpufreq_set_cur_state(unsigned int cpu, int state)
|
|
|
|
{
|
|
|
|
return 0;
|
|
|
|
}
|
2005-04-17 02:20:36 +04:00
|
|
|
|
|
|
|
#endif
|
|
|
|
|
2005-08-05 08:44:28 +04:00
|
|
|
int acpi_processor_get_limit_info(struct acpi_processor *pr)
|
2005-04-17 02:20:36 +04:00
|
|
|
{
|
|
|
|
|
|
|
|
if (!pr)
|
2006-06-27 08:41:40 +04:00
|
|
|
return -EINVAL;
|
2005-04-17 02:20:36 +04:00
|
|
|
|
|
|
|
if (pr->flags.throttling)
|
|
|
|
pr->flags.limit = 1;
|
|
|
|
|
2006-06-27 08:41:40 +04:00
|
|
|
return 0;
|
2005-04-17 02:20:36 +04:00
|
|
|
}
|
|
|
|
|
2008-01-17 10:51:23 +03:00
|
|
|
/* thermal coolign device callbacks */
|
|
|
|
static int acpi_processor_max_state(struct acpi_processor *pr)
|
|
|
|
{
|
|
|
|
int max_state = 0;
|
|
|
|
|
|
|
|
/*
|
|
|
|
* There exists four states according to
|
|
|
|
* cpufreq_thermal_reduction_ptg. 0, 1, 2, 3
|
|
|
|
*/
|
|
|
|
max_state += cpufreq_get_max_state(pr->id);
|
|
|
|
if (pr->flags.throttling)
|
|
|
|
max_state += (pr->throttling.state_count -1);
|
|
|
|
|
|
|
|
return max_state;
|
|
|
|
}
|
|
|
|
static int
|
2008-11-27 20:48:13 +03:00
|
|
|
processor_get_max_state(struct thermal_cooling_device *cdev,
|
|
|
|
unsigned long *state)
|
2008-01-17 10:51:23 +03:00
|
|
|
{
|
|
|
|
struct acpi_device *device = cdev->devdata;
|
2013-03-25 14:50:06 +04:00
|
|
|
struct acpi_processor *pr;
|
2008-01-17 10:51:23 +03:00
|
|
|
|
2013-03-25 14:50:06 +04:00
|
|
|
if (!device)
|
|
|
|
return -EINVAL;
|
|
|
|
|
|
|
|
pr = acpi_driver_data(device);
|
|
|
|
if (!pr)
|
2008-01-17 10:51:23 +03:00
|
|
|
return -EINVAL;
|
|
|
|
|
2008-11-27 20:48:13 +03:00
|
|
|
*state = acpi_processor_max_state(pr);
|
|
|
|
return 0;
|
2008-01-17 10:51:23 +03:00
|
|
|
}
|
|
|
|
|
|
|
|
static int
|
2008-11-27 20:48:13 +03:00
|
|
|
processor_get_cur_state(struct thermal_cooling_device *cdev,
|
|
|
|
unsigned long *cur_state)
|
2008-01-17 10:51:23 +03:00
|
|
|
{
|
|
|
|
struct acpi_device *device = cdev->devdata;
|
2013-03-25 14:50:06 +04:00
|
|
|
struct acpi_processor *pr;
|
2008-01-17 10:51:23 +03:00
|
|
|
|
2013-03-25 14:50:06 +04:00
|
|
|
if (!device)
|
|
|
|
return -EINVAL;
|
|
|
|
|
|
|
|
pr = acpi_driver_data(device);
|
|
|
|
if (!pr)
|
2008-01-17 10:51:23 +03:00
|
|
|
return -EINVAL;
|
|
|
|
|
2008-11-27 20:48:13 +03:00
|
|
|
*cur_state = cpufreq_get_cur_state(pr->id);
|
2008-01-17 10:51:23 +03:00
|
|
|
if (pr->flags.throttling)
|
2008-11-27 20:48:13 +03:00
|
|
|
*cur_state += pr->throttling.state;
|
|
|
|
return 0;
|
2008-01-17 10:51:23 +03:00
|
|
|
}
|
|
|
|
|
|
|
|
static int
|
2008-11-27 20:48:13 +03:00
|
|
|
processor_set_cur_state(struct thermal_cooling_device *cdev,
|
|
|
|
unsigned long state)
|
2008-01-17 10:51:23 +03:00
|
|
|
{
|
|
|
|
struct acpi_device *device = cdev->devdata;
|
2013-03-25 14:50:06 +04:00
|
|
|
struct acpi_processor *pr;
|
2008-01-17 10:51:23 +03:00
|
|
|
int result = 0;
|
|
|
|
int max_pstate;
|
|
|
|
|
2013-03-25 14:50:06 +04:00
|
|
|
if (!device)
|
|
|
|
return -EINVAL;
|
|
|
|
|
|
|
|
pr = acpi_driver_data(device);
|
|
|
|
if (!pr)
|
2008-01-17 10:51:23 +03:00
|
|
|
return -EINVAL;
|
|
|
|
|
|
|
|
max_pstate = cpufreq_get_max_state(pr->id);
|
|
|
|
|
|
|
|
if (state > acpi_processor_max_state(pr))
|
|
|
|
return -EINVAL;
|
|
|
|
|
|
|
|
if (state <= max_pstate) {
|
|
|
|
if (pr->flags.throttling && pr->throttling.state)
|
2009-08-27 01:29:29 +04:00
|
|
|
result = acpi_processor_set_throttling(pr, 0, false);
|
2008-01-17 10:51:23 +03:00
|
|
|
cpufreq_set_cur_state(pr->id, state);
|
|
|
|
} else {
|
|
|
|
cpufreq_set_cur_state(pr->id, max_pstate);
|
|
|
|
result = acpi_processor_set_throttling(pr,
|
2009-08-27 01:29:29 +04:00
|
|
|
state - max_pstate, false);
|
2008-01-17 10:51:23 +03:00
|
|
|
}
|
|
|
|
return result;
|
|
|
|
}
|
|
|
|
|
2011-06-25 21:07:52 +04:00
|
|
|
const struct thermal_cooling_device_ops processor_cooling_ops = {
|
2008-01-17 10:51:23 +03:00
|
|
|
.get_max_state = processor_get_max_state,
|
|
|
|
.get_cur_state = processor_get_cur_state,
|
|
|
|
.set_cur_state = processor_set_cur_state,
|
|
|
|
};
|