Documentation: networking: add cpsw switchdev based driver documentation
A new cpsw dirver based on switchdev was added. Add documentation about basic configuration and future features Signed-off-by: Ilias Apalodimas <ilias.apalodimas@linaro.org> Signed-off-by: Grygorii Strashko <grygorii.strashko@ti.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Родитель
da84e50c8e
Коммит
14c815a9d1
|
@ -0,0 +1,209 @@
|
|||
* Texas Instruments CPSW switchdev based ethernet driver 2.0
|
||||
|
||||
- Port renaming
|
||||
On older udev versions renaming of ethX to swXpY will not be automatically
|
||||
supported
|
||||
In order to rename via udev:
|
||||
ip -d link show dev sw0p1 | grep switchid
|
||||
|
||||
SUBSYSTEM=="net", ACTION=="add", ATTR{phys_switch_id}==<switchid>, \
|
||||
ATTR{phys_port_name}!="", NAME="sw0$attr{phys_port_name}"
|
||||
|
||||
|
||||
====================
|
||||
# Dual mac mode
|
||||
====================
|
||||
- The new (cpsw_new.c) driver is operating in dual-emac mode by default, thus
|
||||
working as 2 individual network interfaces. Main differences from legacy CPSW
|
||||
driver are:
|
||||
- optimized promiscuous mode: The P0_UNI_FLOOD (both ports) is enabled in
|
||||
addition to ALLMULTI (current port) instead of ALE_BYPASS.
|
||||
So, Ports in promiscuous mode will keep possibility of mcast and vlan filtering,
|
||||
which is provides significant benefits when ports are joined to the same bridge,
|
||||
but without enabling "switch" mode, or to different bridges.
|
||||
- learning disabled on ports as it make not too much sense for
|
||||
segregated ports - no forwarding in HW.
|
||||
- enabled basic support for devlink.
|
||||
|
||||
devlink dev show
|
||||
platform/48484000.switch
|
||||
|
||||
devlink dev param show
|
||||
platform/48484000.switch:
|
||||
name switch_mode type driver-specific
|
||||
values:
|
||||
cmode runtime value false
|
||||
name ale_bypass type driver-specific
|
||||
values:
|
||||
cmode runtime value false
|
||||
|
||||
Devlink configuration parameters
|
||||
====================
|
||||
See Documentation/networking/devlink-params-ti-cpsw-switch.txt
|
||||
|
||||
====================
|
||||
# Bridging in dual mac mode
|
||||
====================
|
||||
The dual_mac mode requires two vids to be reserved for internal purposes,
|
||||
which, by default, equal CPSW Port numbers. As result, bridge has to be
|
||||
configured in vlan unaware mode or default_pvid has to be adjusted.
|
||||
|
||||
ip link add name br0 type bridge
|
||||
ip link set dev br0 type bridge vlan_filtering 0
|
||||
echo 0 > /sys/class/net/br0/bridge/default_pvid
|
||||
ip link set dev sw0p1 master br0
|
||||
ip link set dev sw0p2 master br0
|
||||
- or -
|
||||
ip link add name br0 type bridge
|
||||
ip link set dev br0 type bridge vlan_filtering 0
|
||||
echo 100 > /sys/class/net/br0/bridge/default_pvid
|
||||
ip link set dev br0 type bridge vlan_filtering 1
|
||||
ip link set dev sw0p1 master br0
|
||||
ip link set dev sw0p2 master br0
|
||||
|
||||
====================
|
||||
# Enabling "switch"
|
||||
====================
|
||||
The Switch mode can be enabled by configuring devlink driver parameter
|
||||
"switch_mode" to 1/true:
|
||||
devlink dev param set platform/48484000.switch \
|
||||
name switch_mode value 1 cmode runtime
|
||||
|
||||
This can be done regardless of the state of Port's netdev devices - UP/DOWN, but
|
||||
Port's netdev devices have to be in UP before joining to the bridge to avoid
|
||||
overwriting of bridge configuration as CPSW switch driver copletly reloads its
|
||||
configuration when first Port changes its state to UP.
|
||||
|
||||
When the both interfaces joined the bridge - CPSW switch driver will enable
|
||||
marking packets with offload_fwd_mark flag unless "ale_bypass=0"
|
||||
|
||||
All configuration is implemented via switchdev API.
|
||||
|
||||
====================
|
||||
# Bridge setup
|
||||
====================
|
||||
devlink dev param set platform/48484000.switch \
|
||||
name switch_mode value 1 cmode runtime
|
||||
|
||||
ip link add name br0 type bridge
|
||||
ip link set dev br0 type bridge ageing_time 1000
|
||||
ip link set dev sw0p1 up
|
||||
ip link set dev sw0p2 up
|
||||
ip link set dev sw0p1 master br0
|
||||
ip link set dev sw0p2 master br0
|
||||
[*] bridge vlan add dev br0 vid 1 pvid untagged self
|
||||
|
||||
[*] if vlan_filtering=1. where default_pvid=1
|
||||
|
||||
=================
|
||||
# On/off STP
|
||||
=================
|
||||
ip link set dev BRDEV type bridge stp_state 1/0
|
||||
|
||||
Note. Steps [*] are mandatory.
|
||||
|
||||
====================
|
||||
# VLAN configuration
|
||||
====================
|
||||
bridge vlan add dev br0 vid 1 pvid untagged self <---- add cpu port to VLAN 1
|
||||
|
||||
Note. This step is mandatory for bridge/default_pvid.
|
||||
|
||||
=================
|
||||
# Add extra VLANs
|
||||
=================
|
||||
1. untagged:
|
||||
bridge vlan add dev sw0p1 vid 100 pvid untagged master
|
||||
bridge vlan add dev sw0p2 vid 100 pvid untagged master
|
||||
bridge vlan add dev br0 vid 100 pvid untagged self <---- Add cpu port to VLAN100
|
||||
|
||||
2. tagged:
|
||||
bridge vlan add dev sw0p1 vid 100 master
|
||||
bridge vlan add dev sw0p2 vid 100 master
|
||||
bridge vlan add dev br0 vid 100 pvid tagged self <---- Add cpu port to VLAN100
|
||||
|
||||
====
|
||||
FDBs
|
||||
====
|
||||
FDBs are automatically added on the appropriate switch port upon detection
|
||||
|
||||
Manually adding FDBs:
|
||||
bridge fdb add aa:bb:cc:dd:ee:ff dev sw0p1 master vlan 100
|
||||
bridge fdb add aa:bb:cc:dd:ee:fe dev sw0p2 master <---- Add on all VLANs
|
||||
|
||||
====
|
||||
MDBs
|
||||
====
|
||||
MDBs are automatically added on the appropriate switch port upon detection
|
||||
|
||||
Manually adding MDBs:
|
||||
bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent vid 100
|
||||
bridge mdb add dev br0 port sw0p1 grp 239.1.1.1 permanent <---- Add on all VLANs
|
||||
|
||||
==================
|
||||
Multicast flooding
|
||||
==================
|
||||
CPU port mcast_flooding is always on
|
||||
|
||||
Turning flooding on/off on swithch ports:
|
||||
bridge link set dev sw0p1 mcast_flood on/off
|
||||
|
||||
==================
|
||||
Access and Trunk port
|
||||
==================
|
||||
bridge vlan add dev sw0p1 vid 100 pvid untagged master
|
||||
bridge vlan add dev sw0p2 vid 100 master
|
||||
|
||||
|
||||
bridge vlan add dev br0 vid 100 self
|
||||
ip link add link br0 name br0.100 type vlan id 100
|
||||
|
||||
Note. Setting PVID on Bridge device itself working only for
|
||||
default VLAN (default_pvid).
|
||||
|
||||
=====================
|
||||
NFS
|
||||
=====================
|
||||
The only way for NFS to work is by chrooting to a minimal environment when
|
||||
switch configuration that will affect connectivity is needed.
|
||||
Assuming you are booting NFS with eth1 interface(the script is hacky and
|
||||
it's just there to prove NFS is doable).
|
||||
|
||||
setup.sh:
|
||||
#!/bin/sh
|
||||
mkdir proc
|
||||
mount -t proc none /proc
|
||||
ifconfig br0 > /dev/null
|
||||
if [ $? -ne 0 ]; then
|
||||
echo "Setting up bridge"
|
||||
ip link add name br0 type bridge
|
||||
ip link set dev br0 type bridge ageing_time 1000
|
||||
ip link set dev br0 type bridge vlan_filtering 1
|
||||
|
||||
ip link set eth1 down
|
||||
ip link set eth1 name sw0p1
|
||||
ip link set dev sw0p1 up
|
||||
ip link set dev sw0p2 up
|
||||
ip link set dev sw0p2 master br0
|
||||
ip link set dev sw0p1 master br0
|
||||
bridge vlan add dev br0 vid 1 pvid untagged self
|
||||
ifconfig sw0p1 0.0.0.0
|
||||
udhchc -i br0
|
||||
fi
|
||||
umount /proc
|
||||
|
||||
run_nfs.sh:
|
||||
#!/bin/sh
|
||||
mkdir /tmp/root/bin -p
|
||||
mkdir /tmp/root/lib -p
|
||||
|
||||
cp -r /lib/ /tmp/root/
|
||||
cp -r /bin/ /tmp/root/
|
||||
cp /sbin/ip /tmp/root/bin
|
||||
cp /sbin/bridge /tmp/root/bin
|
||||
cp /sbin/ifconfig /tmp/root/bin
|
||||
cp /sbin/udhcpc /tmp/root/bin
|
||||
cp /path/to/setup.sh /tmp/root/bin
|
||||
chroot /tmp/root/ busybox sh /bin/setup.sh
|
||||
|
||||
run ./run_nfs.sh
|
|
@ -0,0 +1,10 @@
|
|||
ale_bypass [DEVICE, DRIVER-SPECIFIC]
|
||||
Allows to enable ALE_CONTROL(4).BYPASS mode for debug purposes.
|
||||
All packets will be sent to the Host port only if enabled.
|
||||
Type: bool
|
||||
Configuration mode: runtime
|
||||
|
||||
switch_mode [DEVICE, DRIVER-SPECIFIC]
|
||||
Enable switch mode
|
||||
Type: bool
|
||||
Configuration mode: runtime
|
Загрузка…
Ссылка в новой задаче